PH-303 Industrial pH/ORP Controller with Dual 4–20mA

Compact industrial pH/ORP controller with two isolated 4–20mA outputs, Pt1000 or NTC10K temperature compensation, and panel, wall or pipe mounting.

Tenber PH-303 pH ORP Controller
ENGINEER-READY WATER QUALITY INSTRUMENT

Built for continuous process monitoring

Compact industrial pH/ORP controller with two isolated 4–20mA outputs, Pt1000 or NTC10K temperature compensation, and panel, wall or pipe mounting.

Key specifications

Measurement Range -2.00 to 16.00 pH / -2000 to 2000 mV
Accuracy ±0.01 pH / ±1 mV
Output 4-20mA
APPLICATION-BASED QUOTATION

Need help confirming the right controller and sensor?

Not sure which controller and sensor fit your process? Send us the liquid, measuring range, temperature, installation method, required output and quantity. We will review the configuration before quotation.

    Start with the essentials. Add technical details only if you already have them.

    Add technical details (optional)

    Technical author: Tenber Technical Team Technical reviewer: Tenber Technical Team Last updated: September 1, 2026 Documentation source: current model manual / technical guide and quality documents. Confirm scope for the supplied model.

    Product Overview

    COMPACT PH / ORP CONTROL

    How to Select the Right Configuration

    Choose PH-303 when the project needs the documented measurement range, Pt1000 or NTC10K temperature compensation, two isolated 4–20mA outputs and the listed installation options. Choose PH-302 when the project also requires RS485 Modbus RTU or two relay controls. Choose PHS-3301 when a larger controller platform with documented Modbus and additional control functions is required.

    Key Functions and Benefits

    Key Functions

    pH, ORP and temperature measurement

    PH-303 supports pH or ORP measurement with temperature input. The documented resolution is 0.01 pH and 1 mV, with temperature compensation using Pt1000 or NTC10K.

    Two isolated analogue outputs

    The selection guide documents two isolated 4–20mA outputs. Confirm the required value mapping, load and receiving-device configuration before wiring the controller into a PLC, recorder or other system.

    Simplified integration

    PH-303 does not include the PH-302 relay outputs or RS485 Modbus RTU communication. Choose the PH-302 when relay control or digital communication is required.

    Verified Technical Specifications

    Verified Technical Specifications

    Measured variablespH or ORP, plus temperature
    pH range−2.00 to +16.00 pH
    ORP range−2000 to +2000 mV
    Resolution0.01 pH / 1 mV
    Accuracy±0.01 pH / ±1 mV
    Temperature range−10 to +130°C
    Temperature compensationPt1000 / NTC10K
    Analogue outputsTwo isolated 4–20mA outputs
    RS485 Modbus RTUNot included on PH-303; compare PH-302 when required
    Relay outputsNot included on PH-303; compare PH-302 when required
    Protection and powerIP65; 90–260VAC; optional DC24V
    InstallationPanel, wall or pipe mounting
    Body and panel opening108 × 108 × 128mm; 92.5 × 92.5mm opening

    Sensor, Range and Compatibility

    Continuous pH, ORP and temperature measurement with dual analogue outputs

    Tenber PH-303 is a compact industrial pH/ORP controller for continuous measurement in wastewater, environmental monitoring, process water and other suitable applications. It measures pH or oxidation-reduction potential together with temperature and provides two isolated 4–20mA outputs for compatible monitoring, recording or automation systems.

    PH-303 uses the same core measurement range as the PH-302 family while omitting the PH-302 relay and RS485 Modbus RTU functions. This simplified configuration is intended for projects that need analogue signals without those additional control and communication features.

    −2–16 pHpH measuring range
    ±2000 mVORP measuring range
    −10–130°CTemperature range
    2 × 4–20mAIsolated outputs

    Electrode and Temperature-Compensation Selection

    PH-303 should be selected together with the pH or ORP electrode, temperature probe, cable and installation arrangement. The nominal pH range does not by itself establish whether an electrode is suitable for the liquid.

    Before quotation, send the liquid composition, expected pH or ORP range, normal and maximum temperature, pressure, installation position, cable length and required analogue-output mapping. For general industrial pH monitoring, compare TB84H0; for selected fluoride-containing applications, review TB84H7W; for ORP measurement, review TB84R1.

    Industrial pH Meter with 4–20mA Output

    PH-303 is suited to projects comparing industrial pH meters with 4–20mA output when the system needs two isolated analogue signals, pH or ORP measurement and temperature compensation. Confirm the output mapping, load, electrode, temperature probe and receiving PLC or recorder before quotation.

    PH-303 Selection Table

    Project requirement PH-303 fit Confirm before quotation
    Measured value pH or ORP plus temperature Active measurement mode and matching electrode
    Analogue integration Two isolated 4–20mA outputs Value mapping, load and receiving PLC/recorder input
    Temperature compensation Pt1000 or NTC10K Probe type and wiring for the selected configuration
    Installation Panel, wall or pipe mounting Mounting method, panel opening and maintenance access
    Digital or relay control Not included on PH-303 Review PH-302 or another documented model if RS485 or relay functions are required

    Use the pH/ORP controller range as the controller hub, compare the sensor and electrode range, and read the industrial wastewater pH electrode guide before sending an application.

    Compatible Sensor Options

    Select the sensor according to the liquid, range, temperature, pressure and installation method. Tenber will confirm the final controller, connector and temperature-compensation configuration before quotation.

    Typical Applications

    Typical Applications

    Wastewater Neutralization

    Monitor pH or ORP during treatment and discharge processes after the electrode is matched to the liquid.

    Environmental and Process Water

    Transmit continuous pH, ORP or temperature values to compatible analogue-input equipment.

    Industrial Process Monitoring

    Use the simplified analogue-output configuration where relay control and RS485 communication are not required.

    Installation, Commissioning and Maintenance

    Installation and Wiring Considerations

    The selection guide lists panel, wall and pipe installation for this 96-series controller. For panel mounting, confirm the available 92.5 × 92.5mm opening and the mounting hardware supplied with the selected configuration.

    Complete the electrode, temperature, two 4–20mA and power wiring checks before applying power. PH-303 does not provide the PH-302 RS485 or relay terminals, so the control system must receive the measurement through the documented analogue outputs. Confirm terminal assignments and output mapping against the current supplied documentation before commissioning.

    Commissioning, Calibration and Maintenance

    1. Confirm the PH-303 model, electrode type, temperature probe, cable and mounting arrangement.
    2. Check the liquid, measurement range, temperature, pressure and installation point before applying power.
    3. Complete the supply, electrode, temperature and analogue-output wiring checks.
    4. Follow the current supplied documentation for pH or ORP calibration and temperature-compensation setup.
    5. Compare the displayed value with a suitable reference check before connecting the analogue outputs to the control system.
    6. Record calibration checks and cleaning observations so the maintenance interval reflects actual fouling and drift.

    Frequently Asked Questions

    Frequently Asked Questions

    Can PH-303 measure both pH and ORP?

    The selection guide identifies pH and ORP measurement ranges for the PH-302/303 family. Confirm the active measurement mode and electrode configuration before ordering.

    Does PH-303 support RS485 Modbus RTU?

    No. The supplied selection guide marks RS485 Modbus RTU as a PH-302 function. Choose PH-302 or another documented Modbus model when digital communication is required.

    Does PH-303 have relay outputs?

    No. The two relay outputs are marked as PH-302 functions in the supplied selection guide. PH-303 is the simplified analogue-output configuration.

    Can PH-303 connect to a PLC?

    It can be considered when the PLC has compatible analogue inputs for the two isolated 4–20mA outputs. Confirm output mapping, load and wiring before ordering.

    Which electrode should I choose?

    Send the liquid composition, pH or ORP range, temperature, pressure, mounting method, cable length and maintenance conditions. The controller and electrode should be checked as one configuration.

    What should be included in a quotation request?

    Provide the measurement parameter, liquid, range, temperature, pressure, installation, required analogue outputs, quantity and destination country.

    Compare the pH and ORP controller range, review wastewater pH monitoring, or browse all Tenber instruments.

    CONTROLLER & SENSOR MATCHING

    Manuals, Related Products and Request for Quotation

    PROJECT SELECTION SUPPORT

    Confirm the PH-303 measuring configuration

    Send the liquid, pH or ORP range, temperature, installation and analogue-output requirements. Tenber will check the controller and electrode combination before quotation.

    Request a Quote

    Selection flow for PH-303

    Start with pH, ORP or temperature measurement, then check the complete measuring loop before quotation.

    1. Define the application and liquid composition.
    2. Record the normal and maximum value, temperature, pressure and flow conditions.
    3. Choose the sensor or electrode, installation method, cable and maintenance access together with the controller.
    4. Confirm the receiving system, including 4–20mA, RS485 Modbus RTU, relay, recorder, PLC or DCS requirements.
    5. Send the quantity, destination country and current documentation requirement for model review.

    Application boundaries

    Use only when the documented two isolated 4–20mA outputs and the selected electrode and temperature arrangement meet the project requirement. Do not assume RS485 or relay functions.

    Inquiry checklist

    Include the liquid, parameter and range, temperature, pressure, installation, sensor or electrode, cable length, output or communication interface, control requirement, quantity and destination country.