PH-302 Industrial pH/ORP Controller
PH-302 industrial pH/ORP controller for wastewater and process monitoring with isolated 4–20mA, RS485 Modbus RTU and two relay…
View specifications →Industrial pH controllers and ORP controllers are selected by the liquid composition, temperature, sensor material, installation and cleaning conditions. Match the controller and electrode together for…
Compare verified specifications and send your process conditions for model selection.
PH-302 industrial pH/ORP controller for wastewater and process monitoring with isolated 4–20mA, RS485 Modbus RTU and two relay…
View specifications →
Compact industrial pH/ORP controller with two isolated 4–20mA outputs, Pt1000 or NTC10K temperature compensation, and panel, wall or…
View specifications →
144 mm industrial pH/ORP controller with dual isolated 4–20mA outputs, RS485 Modbus RTU, three relay functions and 500,000-record…
View specifications →
Dual-channel online pH/ORP controller with two isolated 4–20mA outputs and RS485 Modbus RTU.
View specifications →Industrial pH controllers and ORP controllers are selected by the liquid composition, temperature, sensor material, installation and cleaning conditions. Match the controller and electrode together for wastewater, electroplating and chemical dosing systems.
Wastewater neutralization, electroplating process water, chemical dosing, fermentation and environmental monitoring.
Confirm the measuring range, electrode material, temperature compensation, installation method, cable length and expected cleaning conditions.
Selected models provide 4–20mA, relay and RS485 Modbus RTU options. The exact interface and control functions should be confirmed before quotation.
Review industrial applications, learn about technical service, or send your process conditions for model selection.
Reliable online measurement depends on the complete configuration, not only the controller model.
Pair the controller with an electrode selected for the liquid, temperature and installation. Electroplating and strongly corrosive wastewater may require a chemically resistant body, suitable reference junction and protective holder.
Best suited to neutralization, chemical dosing, electroplating, scrubber circulation and other processes where pH or ORP must be monitored continuously.
See application solutions or send your process conditions for a controller and sensor recommendation.
A controller should be selected together with the sensor, installation and signal requirements. Send the following information so the configuration can be reviewed before quotation.
Selected models provide 4–20mA and RS485 Modbus RTU outputs. Confirm the exact interface when requesting a quotation.
Yes. Send the liquid, range, temperature, pressure and installation method so the controller and sensor can be selected together.
Tenber supports distributor and project enquiries. OEM details are confirmed according to the model and order quantity.
The controller is only one part of the measuring loop. Use this table to narrow the model, then confirm the electrode, temperature compensation, installation and control-system requirements before ordering.
| Model | Measurement | Documented integration | When to consider it |
|---|---|---|---|
| PH-303 | pH −2 to +16 / ORP ±2000 mV / temperature −10 to +130°C | Two isolated 4–20mA outputs | Projects requiring two isolated analogue signals without verified RS485 or relay functions. |
| PH-302 | Selectable pH or ORP, plus temperature | One isolated 4–20mA output, RS485 Modbus RTU and two relay controls | Compact panels that need digital communication as well as analogue and relay functions. |
| PHS-3301 | pH / ORP measurement | Two isolated 4–20mA outputs and RS485 Modbus RTU | 144 mm controller applications that need broader documented integration functions. |
RS485 is model-specific: PH-303 is documented with two isolated 4–20mA outputs, while PH-302 and PHS-3301 documentation identifies RS485 Modbus RTU. Review the sensor and electrode range together with the controller. For a practical comparison, read the industrial pH controller for wastewater 3-model guide.
Start with the liquid composition, expected pH or ORP range, temperature, pressure and fouling conditions. Then select the electrode and installation point.
View wastewater selection guide →Acids, alkalis, fluoride, salts, oils and cleaning chemicals can change the electrode choice even when the controller range looks suitable.
View chemical-process guide →Send the liquid, range, temperature, pressure, mounting, cable, signal, control logic, quantity and destination country.
Discuss your application →