PH-302 pH/ORP Controller with RS485 Modbus

PH-302 industrial pH/ORP controller for wastewater and process monitoring with isolated 4–20mA, RS485 Modbus RTU and two relay controls.

PH-302 Industrial pH/ORP Controller
ENGINEER-READY WATER QUALITY INSTRUMENT

Built for continuous process monitoring

PH-302 industrial pH/ORP controller for wastewater and process monitoring with isolated 4–20mA, RS485 Modbus RTU and two relay controls.

Key specifications

Measurement Range -2.00 to 16.00 pH / -2000 to 2000 mV
Communication RS485 Modbus RTU
Relay 5A/250VAC, 5A/30VDC on selected model
APPLICATION-BASED QUOTATION

Need help confirming the right controller and sensor?

Not sure which controller and sensor fit your process? Send us the liquid, measuring range, temperature, installation method, required output and quantity. We will review the configuration before quotation.

    Start with the essentials. Add technical details only if you already have them.

    Add technical details (optional)

    Technical author: Tenber Technical Team Technical reviewer: Tenber Technical Team Last updated: August 27, 2026 Documentation source: current model manual / technical guide and quality documents. Confirm scope for the supplied model.

    Product Overview

    INDUSTRIAL PH / ORP CONTROL

    PH-302 Industrial pH/ORP Controller for Online Monitoring

    The Tenber PH-302 is an industrial pH/ORP controller for continuous monitoring in wastewater treatment, chemical dosing and process-liquid applications. It supports an isolated 4–20 mA output, RS485 Modbus RTU communication and two relay control points. Panel, wall and pipe mounting options help integrators and plant engineers match the controller to the installation.

    Send your liquid conditions, measurement range and control requirements to confirm the suitable PH-302 controller and electrode configuration.

    −2–16 pHpH measuring range
    ±2000 mVORP measuring range
    −10–130°CTemperature range
    RS485Modbus RTU communication

    How to Select the Right Configuration

    Use PH-302 when the documented −2 to +16 pH or ±2000mV ORP range, one isolated 4–20mA output, RS485 Modbus RTU and two relay controls match the project. Send the liquid composition, expected range, temperature, pressure, mounting method, cable length, control logic and quantity so Tenber can confirm the controller and sensor combination before quotation.

    Key Functions and Benefits

    Key Functions

    pH or ORP measurement

    Select the pH or ORP measurement mode from the controller settings. The documented resolution is 0.01 pH or 1 mV, with a large backlit colour LCD for process readings.

    Analogue and digital signals

    The documented isolated 4–20mA output can be scaled to the selected pH or ORP range. RS485 Modbus RTU communication is available on PH-302 with selectable 9600, 19200 or 38400 baud rates.

    Two relay control points

    Relay 1 and Relay 2 can be configured with separate action and release points. Confirm the required control logic and use suitable external protection for inductive or capacitive loads.

    Verified Technical Specifications

    Verified Technical Specifications

    Measured variablespH or ORP, plus temperature
    pH range−2.00 to +16.00 pH
    ORP range−2000 to +2000 mV
    Resolution0.01 pH / 1 mV / 0.1°C
    Accuracy±0.01 pH / ±1 mV / ±0.2°C
    Temperature compensationPt1000 or NTC10K; manual temperature mode is also documented
    Temperature range−10.0 to +130.0°C; compensation range −10.0 to +130.0°C
    Analogue outputOne isolated 4–20mA output; maximum load 500Ω; output accuracy ±0.05mA
    CommunicationRS485 Modbus RTU; 9600 / 19200 / 38400 baud
    Relay contactsRelay 1 and Relay 2; 5A at 250VAC or 5A at 30VDC
    Protection and powerIP65; 90–260VAC, 50/60Hz; power consumption below 5W
    InstallationPanel, wall or pipe mounting; 92.5 × 92.5mm panel opening; approximately 0.70kg

    Sensor, Range and Compatibility

    Sensor, Temperature and Signal Selection

    PH-302 can be used with a pH or ORP electrode, but the final sensor depends on the liquid, expected range, temperature, pressure, installation method and maintenance conditions. Tenber’s compatible options include TB84H0 for standard industrial pH measurement, TB84H7W for HF-resistant pH applications and TB84R1 for industrial ORP measurement. Confirm the electrode, connector and cable before ordering.

    Choose Pt1000 or NTC10K when automatic temperature compensation is required, or use the documented manual mode when the process arrangement calls for a fixed temperature input. The controller also provides a pH/ORP offset setting; use it only after the displayed value has been checked against an accepted reference.

    Typical Applications

    Typical Applications

    Wastewater Monitoring

    Monitor pH or ORP during neutralization, treatment and discharge processes after the electrode and sample point are matched to the liquid.

    Process and Environmental Water

    Transmit the measurement to compatible PLC, DCS or recording equipment through isolated 4–20mA or RS485 Modbus RTU.

    Fermentation and Food Production

    Use continuous pH or temperature observation where the materials, cleaning conditions and electrode arrangement have been reviewed.

    Installation, Commissioning and Maintenance

    Installation and Wiring Considerations

    The 96-series body supports panel, wall and pipe installation. For panel mounting, prepare a 92.5 × 92.5mm square opening and secure the instrument with the supplied mounting hardware. Install the controller away from high heat, high humidity, corrosive gases, direct sunlight and sources of electrical interference.

    Complete the electrode, temperature, 4–20mA, RS485, relay and power wiring before applying power. The manual identifies the PH/ORP, reference, auxiliary, shield, temperature, current-output and RS485 terminals. Check polarity, signal mapping and the receiving device before connecting the controller to a PLC, DCS, recorder or dosing system.

    Relay contacts can be affected by electrical sparks, especially with inductive or capacitive loads. Follow the manual’s protection guidance and use an appropriately rated external protection circuit where the connected load requires it.

    Commissioning, Calibration and Maintenance

    1. Confirm the controller model, electrode, temperature probe, cable, installation method and signal requirements.
    2. Select pH or ORP mode and configure the temperature-compensation method.
    3. Scale the isolated 4–20mA output to the required measurement range, then verify it with the receiving system.
    4. Set the Modbus address and baud rate when RS485 communication is required.
    5. Configure relay action and release points from the process control requirement, then test both relay outputs before automatic dosing.
    6. Perform the documented two-point pH calibration with suitable standard solutions, or the one-point ORP calibration with a verified standard.
    7. Record inspection, cleaning and calibration checks according to the liquid and electrode condition. The manual notes that an electrode efficiency below 80% indicates ageing and should be reviewed.

    Frequently Asked Questions

    Frequently Asked Questions

    Does PH-302 support both pH and ORP?

    Yes. The manual documents selectable pH and ORP measurement modes. The electrode and settings determine the active measuring arrangement.

    Does PH-302 support RS485 Modbus RTU?

    Yes. PH-302 documents RS485 Modbus RTU communication with selectable 9600, 19200 or 38400 baud rates. Confirm the required address and register mapping for the project.

    How many analogue outputs does PH-302 provide?

    The specification identifies one isolated 4–20mA output with a maximum 500Ω load. Confirm the exact output mapping and supplied variant before ordering.

    Which electrode should I choose?

    Choose from the liquid, pH or ORP range, temperature, pressure, installation and maintenance conditions. TB84H0, TB84H7W and TB84R1 are compatible options shown on this site, subject to final configuration review.

    What should be included in a quotation request?

    Provide the liquid, parameter, range, temperature, pressure, installation method, cable length, output and communication requirements, control logic, quantity and destination country.

    Compare the pH and ORP controller range, review the electroplating pH monitoring case study, or browse the complete Tenber instrument catalog.

    PROJECT SELECTION SUPPORT

    Manuals, Related Products and Request for Quotation

    Confirm the PH-302 measuring configuration

    Send the liquid, pH or ORP range, temperature, installation, signal, communication and control requirements. Tenber will review the controller and electrode combination before quotation.

    Request a Quote

    Selection flow for PH-302

    Start with pH or ORP measurement, then check the complete measuring loop before quotation.

    1. Define the application and liquid composition.
    2. Record the normal and maximum value, temperature, pressure and flow conditions.
    3. Choose the sensor or electrode, installation method, cable and maintenance access together with the controller.
    4. Confirm the receiving system, including 4–20mA, RS485 Modbus RTU, relay, recorder, PLC or DCS requirements.
    5. Send the quantity, destination country and current documentation requirement for model review.

    Application boundaries

    Confirm the electrode, temperature input, analogue output, RS485 Modbus RTU and relay requirements for the supplied variant.

    Inquiry checklist

    Include the liquid, parameter and range, temperature, pressure, installation, sensor or electrode, cable length, output or communication interface, control requirement, quantity and destination country.