Built for continuous process monitoring
Compact industrial pH/ORP controller with one isolated 4–20mA output (500 Ω maximum load; ±0.05 mA output accuracy), Pt1000 or NTC10K temperature compensation, and panel, wall or pipe mounting.
Key specifications
| Measurement Range | -2.00 to 16.00 pH / -2000 to 2000 mV |
| Accuracy | ±0.01 pH / ±1 mV |
| Output | One isolated 4–20mA output; 500 Ω max; ±0.05 mA accuracy |
Need help confirming the right controller and sensor?
For PH-303 inquiries, share the project details below so we can review the configuration before quotation.
- Share the liquid, measuring range, temperature, installation method, required output and quantity.
- We review the controller and sensor configuration before quotation.
- We reply within one working day.
Product Overview
Continuous pH, ORP and temperature measurement with one isolated 4–20mA output
Tenber PH-303 is a compact industrial pH/ORP controller for continuous measurement in wastewater, environmental monitoring, process water and other suitable applications. It measures pH or oxidation-reduction potential together with temperature and provides one isolated 4–20mA output for compatible monitoring, recording or automation systems.
PH-303 uses the same core measurement range as the PH-302 family while omitting the PH-302 relay and RS485 Modbus RTU functions. This simplified configuration is intended for projects that need analogue signals without those additional control and communication features.
How to Select the Right Configuration
Choose PH-303 when the project needs the documented measurement range, Pt1000 or NTC10K temperature compensation, one isolated 4–20mA output and the listed installation options. Choose PH-302 when the project also requires RS485 Modbus RTU or two relay controls. Choose PHS-3301 when a larger controller platform with documented Modbus and additional control functions is required.
PH-303 Selection Table
| Project requirement | PH-303 fit | Confirm before quotation |
|---|---|---|
| Measured value | pH or ORP plus temperature | Active measurement mode and matching electrode |
| Analogue integration | One isolated 4–20mA output | Value mapping, load and receiving PLC/recorder input |
| Temperature compensation | Pt1000 or NTC10K | Probe type and wiring for the selected configuration |
| Installation | Panel, wall or pipe mounting | Mounting method, panel opening and maintenance access |
| Digital or relay control | Not included on PH-303 | Review PH-302 or another documented model if RS485 or relay functions are required |
Use the pH/ORP controller range as the controller hub, compare the sensor and electrode range, and read the industrial wastewater pH electrode guide before sending an application.
Key Functions and Benefits
Key Functions
pH, ORP and temperature measurement
PH-303 supports pH or ORP measurement with temperature input. The documented resolution is 0.01 pH and 1 mV, with temperature compensation using Pt1000 or NTC10K.
One isolated analogue output
The current PH-303 manual documents one isolated 4–20mA output; it does not identify a second analogue channel. Confirm the required value mapping, load and receiving-device configuration before wiring the controller into a PLC, recorder or other system.
Simplified integration
PH-303 does not include the PH-302 relay outputs or RS485 Modbus RTU communication. Choose the PH-302 when relay control or digital communication is required.
Verified Technical Specifications
Verified Technical Specifications
Sensor, Range and Compatibility
Electrode and Temperature-Compensation Selection
PH-303 should be selected together with the pH or ORP electrode, temperature probe, cable and installation arrangement. The nominal pH range does not by itself establish whether an electrode is suitable for the liquid.
Before quotation, send the liquid composition, expected pH or ORP range, normal and maximum temperature, pressure, installation position, cable length and required analogue-output mapping. For general industrial pH monitoring, compare TB84H0; for selected fluoride-containing applications, review TB84H7W; for ORP measurement, review TB84R1.
Industrial pH Meter with 4–20mA Output
PH-303 is suited to projects comparing industrial pH meters with 4–20mA output when the system needs one isolated analogue signal, pH or ORP measurement and temperature compensation. Confirm the output mapping, load, electrode, temperature probe and receiving PLC or recorder before quotation.
Compatible Sensor Options
Select the sensor according to the liquid, range, temperature, pressure and installation method. Tenber will confirm the final controller, connector and temperature-compensation configuration before quotation.
TB84H0Tenber TB84H0W Chemical-Grade pH ElectrodeStandard industrial pH measurementView sensor details →
TB84H7WTenber TB84H7W HF-Resistant pH SensorHF-resistant pH applicationsView sensor details →
TB84R1Tenber TB84R1 Industrial ORP SensorIndustrial ORP measurementView sensor details →Typical Applications
Water treatment
Continuous monitoring at a suitable treatment or process-water point after the measuring loop is confirmed.
Industrial process control
Transmit the documented measurement to compatible automation, recording or supervisory equipment.
Project-based integration
Confirm liquid conditions, range, installation and signals before the controller and sensor are supplied.
Installation, Commissioning and Maintenance
Follow the current model-matched English manual for mounting, wiring, commissioning, calibration, cleaning and maintenance. Confirm the supplied variant and isolate power before wiring. Verify output scaling and receiving-system settings before enabling automatic control.
Model Selection and Inquiry Information
Include the following information in a quotation request:
- Measured liquid and application
- Normal, minimum and maximum measuring range
- Temperature, pressure and fouling conditions
- Sensor or electrode, installation method and cable length
- Required analogue, digital, relay or alarm signals
- Quantity, destination and commissioning requirements
Frequently Asked Questions
How do I confirm whether this model suits my process?
Send the liquid, range, temperature, pressure, installation and required signals. Tenber will review the complete controller and sensor configuration before quotation.
Can I use another sensor or controller configuration?
Do not assume interchangeability. Confirm the sensor, range, temperature input, wiring and supplied model against the current model-matched manual.
Which document should be followed for installation?
Use the current English manual linked on this page for the exact model. Request confirmation if the supplied variant or project conditions differ.
Related Resources and Request for Quotation
Use the current English manual linked above for installation and commissioning. For model selection or quotation, send the process conditions and required interface details.