PH-303 Industrial pH/ORP Controller with 4–20mA Output

Compact industrial pH/ORP controller with one isolated 4–20mA output (500 Ω maximum load; ±0.05 mA output accuracy), Pt1000 or NTC10K temperature compensation, and panel, wall or pipe mounting.

Tenber PH-303 pH ORP Controller
ENGINEER-READY WATER QUALITY INSTRUMENT

Built for continuous process monitoring

Compact industrial pH/ORP controller with one isolated 4–20mA output (500 Ω maximum load; ±0.05 mA output accuracy), Pt1000 or NTC10K temperature compensation, and panel, wall or pipe mounting.

Key specifications

Measurement Range -2.00 to 16.00 pH / -2000 to 2000 mV
Accuracy ±0.01 pH / ±1 mV
Output One isolated 4–20mA output; 500 Ω max; ±0.05 mA accuracy
APPLICATION-BASED QUOTATION

Need help confirming the right controller and sensor?

For PH-303 inquiries, share the project details below so we can review the configuration before quotation.

What happens after you contact us?
  1. Share the liquid, measuring range, temperature, installation method, required output and quantity.
  2. We review the controller and sensor configuration before quotation.
  3. We reply within one working day.

    Start with the essentials. Add technical details only if you already have them.

    Add technical details (optional)

    Technical author: Kaiwen Wu, TENBER Technical review: Kaiwen Wu, International Business — scope and model-selection review Last updated: November 9, 2026 Documentation source: current model manual / technical guide and quality documents. Confirm scope for the supplied model.

    Product Overview

    COMPACT PH / ORP CONTROL

    Continuous pH, ORP and temperature measurement with one isolated 4–20mA output

    Tenber PH-303 is a compact industrial pH/ORP controller for continuous measurement in wastewater, environmental monitoring, process water and other suitable applications. It measures pH or oxidation-reduction potential together with temperature and provides one isolated 4–20mA output for compatible monitoring, recording or automation systems.

    PH-303 uses the same core measurement range as the PH-302 family while omitting the PH-302 relay and RS485 Modbus RTU functions. This simplified configuration is intended for projects that need analogue signals without those additional control and communication features.

    −2–16 pHpH measuring range
    ±2000 mVORP measuring range
    −10–130°CTemperature range
    1 × 4–20mAIsolated outputs

    How to Select the Right Configuration

    Choose PH-303 when the project needs the documented measurement range, Pt1000 or NTC10K temperature compensation, one isolated 4–20mA output and the listed installation options. Choose PH-302 when the project also requires RS485 Modbus RTU or two relay controls. Choose PHS-3301 when a larger controller platform with documented Modbus and additional control functions is required.

    PH-303 Selection Table

    Project requirement PH-303 fit Confirm before quotation
    Measured value pH or ORP plus temperature Active measurement mode and matching electrode
    Analogue integration One isolated 4–20mA output Value mapping, load and receiving PLC/recorder input
    Temperature compensation Pt1000 or NTC10K Probe type and wiring for the selected configuration
    Installation Panel, wall or pipe mounting Mounting method, panel opening and maintenance access
    Digital or relay control Not included on PH-303 Review PH-302 or another documented model if RS485 or relay functions are required

    Use the pH/ORP controller range as the controller hub, compare the sensor and electrode range, and read the industrial wastewater pH electrode guide before sending an application.

    Key Functions and Benefits

    Key Functions

    pH, ORP and temperature measurement

    PH-303 supports pH or ORP measurement with temperature input. The documented resolution is 0.01 pH and 1 mV, with temperature compensation using Pt1000 or NTC10K.

    One isolated analogue output

    The current PH-303 manual documents one isolated 4–20mA output; it does not identify a second analogue channel. Confirm the required value mapping, load and receiving-device configuration before wiring the controller into a PLC, recorder or other system.

    Simplified integration

    PH-303 does not include the PH-302 relay outputs or RS485 Modbus RTU communication. Choose the PH-302 when relay control or digital communication is required.

    Verified Technical Specifications

    Verified Technical Specifications

    Measured variablespH or ORP, plus temperature
    pH range−2.00 to +16.00 pH
    ORP range−2000 to +2000 mV
    Resolution0.01 pH / 1 mV
    Accuracy±0.01 pH / ±1 mV
    Temperature range−10 to +130°C
    Temperature compensationPt1000 / NTC10K
    Analogue outputOne isolated 4–20mA output; max. load 500 Ω; accuracy ±0.05 mA
    RS485 Modbus RTUNot included on PH-303; compare PH-302 when required
    Relay outputsNot included on PH-303; compare PH-302 when required
    Protection and powerIP65; 90–260 VAC; power less than 5 W
    InstallationPanel, wall or pipe mounting
    Body and panel opening108 × 108 × 128mm; 92.5 × 92.5mm opening

    Sensor, Range and Compatibility

    Electrode and Temperature-Compensation Selection

    PH-303 should be selected together with the pH or ORP electrode, temperature probe, cable and installation arrangement. The nominal pH range does not by itself establish whether an electrode is suitable for the liquid.

    Before quotation, send the liquid composition, expected pH or ORP range, normal and maximum temperature, pressure, installation position, cable length and required analogue-output mapping. For general industrial pH monitoring, compare TB84H0; for selected fluoride-containing applications, review TB84H7W; for ORP measurement, review TB84R1.

    Industrial pH Meter with 4–20mA Output

    PH-303 is suited to projects comparing industrial pH meters with 4–20mA output when the system needs one isolated analogue signal, pH or ORP measurement and temperature compensation. Confirm the output mapping, load, electrode, temperature probe and receiving PLC or recorder before quotation.

    Compatible Sensor Options

    Select the sensor according to the liquid, range, temperature, pressure and installation method. Tenber will confirm the final controller, connector and temperature-compensation configuration before quotation.

    Typical Applications

    Water treatment

    Continuous monitoring at a suitable treatment or process-water point after the measuring loop is confirmed.

    Industrial process control

    Transmit the documented measurement to compatible automation, recording or supervisory equipment.

    Project-based integration

    Confirm liquid conditions, range, installation and signals before the controller and sensor are supplied.

    Installation, Commissioning and Maintenance

    Follow the current model-matched English manual for mounting, wiring, commissioning, calibration, cleaning and maintenance. Confirm the supplied variant and isolate power before wiring. Verify output scaling and receiving-system settings before enabling automatic control.

    Model Selection and Inquiry Information

    Include the following information in a quotation request:

    Frequently Asked Questions

    How do I confirm whether this model suits my process?

    Send the liquid, range, temperature, pressure, installation and required signals. Tenber will review the complete controller and sensor configuration before quotation.

    Can I use another sensor or controller configuration?

    Do not assume interchangeability. Confirm the sensor, range, temperature input, wiring and supplied model against the current model-matched manual.

    Which document should be followed for installation?

    Use the current English manual linked on this page for the exact model. Request confirmation if the supplied variant or project conditions differ.

    Related Resources and Request for Quotation

    Use the current English manual linked above for installation and commissioning. For model selection or quotation, send the process conditions and required interface details.

    Request a Quote