Tenber ECS-7301

ECS-7301 Conductivity, TDS & Salinity Meter

Industrial conductivity meter for EC, resistivity, salinity and TDS measurement with dual 4–20mA and RS485 Modbus RTU outputs.

Tenber ECS-7301 Conductivity Meter
ENGINEER-READY WATER QUALITY INSTRUMENT

Built for continuous process monitoring

Industrial conductivity meter for EC, resistivity, salinity and TDS measurement with dual 4–20mA and RS485 Modbus RTU outputs.

Key specifications

Function EC / resistivity / salinity / TDS
Accuracy ±1% F.S.
Output Dual 4-20mA and RS485 Modbus RTU
APPLICATION-BASED QUOTATION

Need help confirming the right controller and sensor?

Not sure which controller and sensor fit your process? Send us the liquid, measuring range, temperature, installation method, required output and quantity. We will review the configuration before quotation.

    Start with the essentials. Add technical details only if you already have them.

    Add technical details (optional)

    Technical author: Tenber Technical Team Technical reviewer: Tenber Technical Team Last updated: September 4, 2026 Documentation source: current model manual / technical guide and quality documents. Confirm scope for the supplied model.

    Product Overview

    ONLINE CONDUCTIVITY ANALYSIS

    Multi-mode conductivity monitoring for industrial water systems

    Tenber ECS-7301 measures conductivity, resistivity, salinity and TDS for wastewater, environmental monitoring and process-water applications. Dual isolated 4–20mA outputs and RS485 Modbus RTU support integration with compatible automation systems.

    EC / TDSWater-quality modes
    ResistivityPure-water monitoring
    ±1% F.S.Verified accuracy
    RS485Modbus RTU

    Key Functions and Benefits

    Key Benefits

    Multiple Measurement Modes

    One controller platform covers conductivity, resistivity, salinity and TDS monitoring requirements.

    Automation Integration

    Dual isolated 4–20mA and RS485 Modbus RTU outputs support compatible PLC and SCADA systems.

    Sensor Matching Support

    The sensor range and cell constant should be selected according to the expected conductivity and process conditions.

    Verified Technical Specifications

    Verified Technical Data

    FunctionsConductivity / resistivity / salinity / TDS
    Accuracy±1% F.S.
    Analog outputDual isolated 4–20mA
    CommunicationRS485 Modbus RTU
    Typical applicationsWastewater, environmental monitoring and process water

    Typical Applications

    Typical Applications

    RO & Pure Water

    Monitor conductivity or resistivity before and after membrane and purification stages.

    Wastewater Treatment

    Track changes in dissolved ionic content across treatment and discharge processes.

    Electroplating Rinse Water

    Conductivity monitoring can help follow rinse-water quality and process changes after the correct sensor range is confirmed.

    Frequently Asked Questions

    Frequently Asked Questions

    Can ECS-7301 connect to a PLC or SCADA system?

    Yes. The verified outputs include dual isolated 4–20mA and RS485 Modbus RTU. Confirm the required communication settings during model selection.

    Can it measure pure water?

    The controller supports resistivity measurement, but the correct sensor and measuring range must be confirmed for the expected water quality.

    How do I choose the conductivity sensor?

    Provide the expected minimum and maximum conductivity, liquid, temperature, pressure and installation method. These conditions determine the appropriate sensor range.

    Can it be used in electroplating?

    It can be considered for rinse-water and related conductivity monitoring. Confirm the chemical composition and measuring range before ordering.

    What should be included in the inquiry?

    Send the application, measuring range, medium, temperature, pressure, signal, installation method and quantity.

    PROJECT SELECTION SUPPORT

    Manuals, Related Products and Request for Quotation

    Need help confirming the right model?

    Send the liquid, measuring range, temperature, pressure, installation method, output signal and quantity. Tenber will check the configuration before quotation.

    Request a Quote

    Selection flow for ECS-7301

    Start with conductivity-related measurement, then check the complete measuring loop before quotation.

    1. Define the application and liquid composition.
    2. Record the normal and maximum value, temperature, pressure and flow conditions.
    3. Choose the sensor or electrode, installation method, cable and maintenance access together with the controller.
    4. Confirm the receiving system, including 4–20mA, RS485 Modbus RTU, relay, recorder, PLC or DCS requirements.
    5. Send the quantity, destination country and current documentation requirement for model review.

    Application boundaries

    Confirm the measurement mode, cell constant, range, temperature compensation, outputs and installation for the supplied ECS-7301 configuration.

    Inquiry checklist

    Include the liquid, parameter and range, temperature, pressure, installation, sensor or electrode, cable length, output or communication interface, control requirement, quantity and destination country.